92 nte electronics, inc. v oice (973) 74 8 ? 508 9 f ax (973) 74 8 ? 622 4 http://www .nteinc.com circuit breakers r58 series features . 250 ? (6 . 35mm) qui ck c onn ect t erm ina ls cannot be manually t rippe d v isual t rip indicato r push button to reset breake r note: indicator plate shown may not be available on all devices . nte t ype no. current rating amps maximuml resistance ohms r5 8 ? 1 a 1 .0 1 .35 (t yp) r5 8 ? 2 a 2 .0 0 .32 (t yp) r5 8 ? 3 a 3 .0 0 .225 r5 8 ? 4 a 4 .0 0 .225 r5 8 ? 5 a 5 .0 0 .225 r5 8 ? 6 a 6 .0 0 .175 r5 8 ? 7 a 7 .0 0 .175 r5 8 ? 8 a 8 .0 0 .175 r5 8 ? 10 a 10 .0 0 .125 r5 8 ? 12 a 12 .0 0 .050 r5 8 ? 15 a 15 .0 0 .040 r5 8 ? 20 a 20 .0 0 .030 r5 8 ? 25 a 25 .0 0 .020 r5 8 ? 30 a 30 .0 0 .020 r5 8 ? 35 a 35 .0 0 .020 t rip t imes 1 to 4 amp t ypes 5 to 35 amp t ypes rated load t rip t imes rated load t rip t imes 100% no t rip 100% no t rip 145% t rip in 1 hour 145% t rip in 1 hour 200% 10 to 45 sec. 200% 6.0 to 30 sec. 400% 3.0 to 14.0 sec. 400% 1 .6 to 4 .5 se c. 600% 1 .4 to 7 .0 se c. 600% 0.60 to 1.7 sec. 800% 0.75 to 4.3 sec. 800% 0.25 to 0.90 sec. 1000% 0.50 to 3.4 sec. 1000% 0.15 to 0.65 sec. accessories nte type no. description r5 8 ? boot (note 1 ) protective boot w/m1 1 thread, clear silicon, w aterproof note 1. not for use with 1a and 2a types. thermal circuit breaker D40 .05 0 (1.27) ma x closed position 1.375 (34.93) .440 (1 1.18) .660 (16.76 ) 1.375 (34.93) .500 (12.7 ) .425 (10.8) .850 (21.59) .312 (7.92 ) m 1 1*1 thread (note ) he x nu t knurled nut t u n d e l r u n k t u n x e h .556 (14.12) .625 (15.88) ) 8 1 . 3 ( 5 2 1 . ) 8 9 . 1 ( 8 7 0 . flat s t raigh t knur l 24 pi t c h note: 1a and 2a types have a 7/1 6 ? 28 threa d electrical specifications electrical characteristics (@ 25 c) calibration: will continuously carry 100% of rating . may trip between 101% and 144%, but must trip at 145 % of rating at +2 5 c maximum operating v oltages: 50 vdc; 250 v ac, @ 50/60 h z dielectric strength : 1500 v ac rm s resettable overload capacity: t en times rated curren t interrupt capacity : 2000 am p s a t 50 v d c 1000 amps at 250 v ac mechanical characteristics t ermination: . 250 (6 . 35) q uick connec t t erminal s shock: withstands to 10 g endurance cycling : over 1000 cycles at 200% of rated load . v ibration: withstands to 10 g at 10 to 55 hz . w eight: less than 1.5 ozs. (42.5 g )
|